Show simple item record

dc.contributor.authorLamu, Admassu N.
dc.contributor.authorBjörkman, Lars
dc.contributor.authorHamre, Harald Johan
dc.contributor.authorAlræk, Terje
dc.contributor.authorMusial, Frauke
dc.contributor.authorRobberstad, Bjarne
dc.date.accessioned2021-09-03T09:15:34Z
dc.date.available2021-09-03T09:15:34Z
dc.date.created2021-07-16T17:19:42Z
dc.date.issued2021
dc.identifier.citationHealth and Quality of Life Outcomes. 2021, 19 (1), 1-12.en_US
dc.identifier.issn1477-7525
dc.identifier.urihttps://hdl.handle.net/11250/2772787
dc.description.abstractBackground Evidence of health utility changes in patients who suffer from longstanding health complaints attributed to dental amalgam fillings are limited. The change in health utility outcomes enables calculating quality-adjusted life-year (QALY) and facilitates the comparison with other health conditions. The purpose of this study was to estimate the validity and responsiveness of the EQ-5D-5L and SF-6D utilities following removal of dental amalgam fillings in patients with health complaints attributed to their amalgam fillings, and examine the ability of these instruments to detect minimally important changes over time. Methods Patients with medically unexplained physical symptoms, which they attributed to dental amalgam restorations, were recruited to a prospective cohort study in Norway. Two health state utility instruments, EQ-5D-5L and SF-6D, as well as self-reported general health complaints (GHC-index) and visual analogue scale (EQ-VAS) were administered to all patients (n = 32) at baseline and at follow-up. The last two were used as criteria measures. Concurrent and predictive validities were examined using correlation coefficients. Responsiveness was assessed by the effect size (ES), standardized response mean (SRM), and relative efficiency. Minimally important change (MIC) was examined by distribution and anchor-based approaches. Results Concurrent validity of the EQ-5D-5L was similar to that of SF-6D utility. EQ-5D-5L was more responsive than SF-6D: the ES were 0.73 and 0.58 for EQ-5D-5L and SF-6D, respectively; SRM were 0.76 and 0.67, respectively. EQ-5D-5L was more efficient than SF-6D in detecting changes, but both were less efficient compared to criteria-based measures. The estimated MIC of EQ-5D-5L value set was 0.108 and 0.118 based on distribution and anchor-based approaches, respectively. The corresponding values for SF-6D were 0.048 and 0.064, respectively. Conclusions In patients with health complaints attributed to dental amalgam undergoing amalgam removal, both EQ-5D-5L and SF-6D showed reasonable concurrent and predictive validity and acceptable responsiveness. The EQ-5D-5L utility appears to be more responsive compared to SF-6D.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleValidity and responsiveness of EQ-5D-5L and SF-6D in patients with health complaints attributed to their amalgam fillings: a prospective cohort study of patients undergoing amalgam removalen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.rights.holderCopyright © 2021, Authors
dc.description.versionpublishedVersionen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1186/s12955-021-01762-4
dc.identifier.cristin1921969
dc.source.journalHealth and Quality of Life Outcomesen_US
dc.source.volume19en_US
dc.source.issue1en_US
dc.source.pagenumber1-12en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal